hp msa1000 end of life. xx is required for Secure Path 4. hp msa1000 end of life

 
xx is required for Secure Path 4hp msa1000 end of life  Controller display with status indicators (2) and push buttons (4) on front of controller

Solved: MSA1000 - Active/Active or Active/Passive - Hewlett Packard Enterprise Community Solved: Hello, In the first quarter of this year I put into place a 4. I am attempting to upgrade the firmware on a couple of msa1000's that I have but have hit a snag, when I run the "firmwareupload" command and answer it questions, it starts to download the new file but fails at the end. HPE refreshes the marketplace with products every year designed to replace HP EOSL or EOL systems. 00 which set the controllers in ACTIVE/ACTIVE mode. HP StorageWorks Modular Smart Array 1500 cs - Installation Procedures. Additionally, keep in mind not to publicly post personal information (serial numbers and case details). 2TB is your limit. When the switch came online, it seemed to work; HP Systems Insight Manager showed that the switch was up and I could see it in the Switch. The servers have NetWare OES (V6. Since you have a mix of read/write applications. End of Support (EOS) The product is Supported, but customer should expect to be able to try to replicate any reported issue on the currently Supported version of the software in their production environment. Poly realizes that the End of Life milestone dates of Poly products impact our customer’s products. Hi Folks - I know a number of you out there use the HP MSA1000 in some capacity, so I figured I'd pass along the word that the Active/Active firmware Blogs PodcastsDoes HP make a 24-bay MSA P2000?? Thank you, Tom. The HP P2000 G3 MSA Array Systems began the End of Life (EOL) process on 30 September 2014. ?. Solutions . 0, W2K, W2K3) VCP (ESX2, Vi3, vSphere4, vSphere5, vSphere 6. HP Enterprise (HPE) supports servers, switches, routers and enterprise storage devices. Could I purchase a secure path software when I use "HP MPIO Basic Failover V1. Step 1: Review and confirm the steps. Typically the end of life will become public when it has happened. . I know that the system is on line. DESCRIPTION. I try to use command line interface to configure the connection and raid but fail. With the MSA1500cs they fixed this p. The HPE MSA 1050 SAN Storage EOL and EOSL can have an impact on your data center ops, but you have continuity options. What options do I have to present this storage another server, something like a DL360/380? the only fiber switch we had. Designed to reduce the complexity, expense, and. Try to find the serial/RJ-45z cable to the front of the MSA1000-controller. Jun 23, 2021. DESCRIPTION. Leave this field blank. After installing Windows 2k Advanced server, we installed the needed drivers for the the fiber controller of the MSA driver software. After the EOSL date, it will not be possible to get support from HP regarding the following areas: Advancements to the HPE MSA Gen 6 Architecture Updates to HPE MSA deliver benefits that help to meet the needs of SMBs, including automatic tiering for faster data access, an improved MSA Health Check tool that eliminates common causes of downtime, and integration with HPE Cloud Volumes Backup for cloud backup and data archival. 4. if one of the hosts runs HP-UX or SCO you cannot mix OS'es: "HP-UX PA-Risc and Itanium-based server support. " Maria Halt. Server is running HPUX 11i and has two hba cards that attached and it sees them in ioscan. zip Has somebody a runnig linux configuration with active/passive MSA 1000 an Qlogic HBA? They will likely request information from you in order to look up your case details or product serial number. Server 2003. Now I need to reconfigure the MSA1000 with new arrays but I. Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. xx now. I would like to migrate to A/A configuration with V7. The read + write must equal 100. Rack Units. 11), following LUNs are created; => controller serialnumber=P56350DX3PS01S logicaldrive all show MSA1000 at SGM05020J9 array A logicaldrive 1. Which is DAS. Find accurate end of life & end of service life dates for HPE MSA2060 hardware. Configuration Support website for details on components that make up a valid cluster configuration. Stop bits: 1. Has anyone experienced this be. hp StorageWorks Modular Smart Array 1000 (MSA1000) Controller First Edition (September 2003) Part Number: 347281-001 This guide provides the user with. The first possibility is to store the disk configuration in memory associated with the card, perhaps with the BIOS configuration or on non-volatile storage on the card itself. 10/31/2022. - MSA1000 (FW V. Skip to Content Skip to Footer. 32 (Sep. Third Edition (May 2006) Part Number: 347282-003 This guide details the Command Line Interface (CLI), which is used to configure and manage the following products: — HP. Explore small business IT solutions. drives in a single 4U rackmount cabinet. On the RP server I have a fc card part no A6795A, The MSA is link up to the rp and n-class via 2GB fibre . Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. 20 active/standby, with two 2/8 FC switches integrated into the rear of the MSA chassis. The MSA is with the module that have a single port too. Health & Life Sciences; Manufacturing; Telecommunications;. . Get in touch. HPE MSA 2050 SAN Storage: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Array 1000 (MSA1000), the Modular Smart Array 500 (MSA500), and the Modular Smart Array 30 (MSA30). This notice is to explain the various stages of. Hi Folks, we have 1 HP MSA 2042 and (4) DL380 g9 servers, warranty expired on all devices few months ago. Park Place Technologies makes it easy to find the latest End of Life (EOL) and End of Service Life (EOSL) information for your HPE hardware. Hi Guys, Can anyone of you help, I have a MSA1000 attach to a rp7400 and a N4000. IT for Data & Analytics. I do not, however, see exactly what this firwmare does for me. The MSA1000 SAN Starter Kit provides an easy and inexpensive way to build a Storage Area Network. - Device Mapper Multipath Configuratin Guide for HP StorageWorks Arrays c00814876. . The HP P2000 G3 MSA Array Systems began the End of Life (EOL) process on 30 September 2014. I want to add more disks on first two arrays which are on first bay. I currently am running an MSA1000 with a single controller and one external Brocade switch. Email. Step 3: Install MSA1500 cs option kits. Connected to this are two MSA30's with 14 disks in each enclosure. The M575 has already been replaced by the M577 and now the M578. In the acu message state I read from ten days: #785 " Background parity initialization is currently queued or in progress on logical drive 2 ( RAID 5 ADG). How should I configure the 2 Sw. 2. Hey All, So, i know the MSA1000 is a dog, but i couldn't beleive its this slow. Max Logical Drive Size: 2. 04-02-2009 02:09 AM. Buying Pre-owned extends a product's life, reducing e-waste and raw material extraction. Tom Howarth. DESCRIPTION. On the RP server I have a fc card part no A6795A, The MSA is link up to the rp and n-class via 2GB fibre . xx version of firmware is available for the MSA-1000. one bay is completely full and other is half empty. Hello, I got an msa1000 in a windows cluster configuration. And any other switches mostly used? Regs KhanThis is a very weird problem that I thought I would see if anyone has seen. Can I mirror disks across the two enclosures? 2. 48 in active/passive configuration. HPE MSA 1050 2050 2052 1060 2060 and. 11 MSA1000 Firmware. MSA1000 offers Multi-platform server support to allow a broad range of servers to take advantage of the MSA1000's scalability, flexibility and connectivity, and supports ACU and Insight Manager. This manual comes under the category controllers and has been rated by 1 people with an average of a 7. The part may also be used in other HP products. 84 TB of embedded flash capacity, you can scale the system from there with any combination of solid state disks (SSD), high-performance Enterprise SAS HDDs, or lower-cost Midline SAS. I wanted to upgrade all firmware and drivers. MSA1000. . HP ProDesk 600 G4. Close. HP, Compaq, StorageWorks, Smart Array, SupportPaq, and the HP and Compaq logo are. What is the End of Life / Service for this SAN?? check out the D2700 enclosure, should be fully compatible with a P2000G3 (25 - 2. The following command displays the World Wide Names of each Host Bus Adapter (HBA) attached to the HP StorageWorks MSA1000. Reference Guide HP StorageWorks 1000 Modular Smart Array Second Edition (July 2006) Part Number: 347280-002 The HP StorageWorks 1000 Modular Smart Array (MSA1000) is a 2-Gb Fibre Channel storage system designed for the entry-level to mid-range Storage Area Network (SAN). i have decided to have one active spare for 42 disks. Site had to power off all system components. Campus and Branch Networking. x) RHCE NPP3 (Nutanix Platform Professional). Need an advice on this: how to know which MSA LUN corresponds to which Windows disk? Thanks a lot, Gera BDCI have a MSA 1000 storage array controller with dual controllers connected via fiber to two HP-UX servers. the MSA1000 is well. . See the documentation for your product for detailed replacement instructions. Allowing you to extend the support cycle and maximize the value of your hardware by saving 30 - 40% against that HPE contract. The SAN storage subsystem will have redundant features (i. 48 is compatible with 4/16 Brocade firmware v5. What utility do I run? I am on HPUX 11. QuickSpecs HP MSA P2000 G3 Modular Smart Array Systems Overview c04168365 — DA – 13551 Worldwide — Version 42 — December 1, 2014 Page 1. According to customer advisory "c01632044 - HP StorageWorks 2000fc Modular Smart Array - SCSI Maintenance Command Completed: cmd = UseCDBNDW drive = Channel:x ID:yy SN:XXXXXXXX Encl:a Slot:b Command Failed" ""To stop the Initialize or Verify utility, go to the Abort A Vdisk Utility page. I recognize with the MSA1500 I have the abilitiy to add the MSA20 for SATA. I can see the old arrays created in the storage trought the OS disk managment (windows 2000). HPE CommunityThe end question is, specifically what would be the expected useful life of an HP MSA 1000 controller board? I had one "go nuts" recently, and it was suggested that it was past its expected life. Procurri makes it easy to find the latest End of Service Life (EOSL) dates for your HPE hardware. Interestingly, the MSA1500 QuickSpecs contain information on the MSA1000 that the MSA1000. Request a quote from our team today. Strategic TPM and ITAD solutions grant you the technical support and flexibility you need, long after EOSL is announced. – jscott. I like a clean bowl & Never go with the zero. But when i directly connects MSA 1000 to Server (HP-DL 380) it works to access storage. 32 Build 300 Hardware 7 Controller Identifer: 41 NODE_ID = 500805F3-000D2DC0 SCSI_VERSION = SCSI-3 Supported Redundancy Mode: Active/Standby Current Redundancy Mode: Active/Standby Current Role: Active Device Port SCSI address 7 Terminal speed for the CLI is set to. Try the command "disable this_controller" or "disable standby". Once power was restored, the the MSA1000 was powered up, it was discovered that the contollers has reset the Connection Profile back to factory default and the Unit_id's were also gone. After speaking to VMWare they stated that they can only provide support on har. Hi all, I've got a full blown SAN going with 2 MSA1000's on it. Microsoft Windows Server 2003. With the introduction of the fifth generation of the HPE MSA Storage product portfolio in May 2017, the fourth generation of HPE MSA 1040, 2040 and 2042 Storage arrays will begin their End of Life (EOL) process on 8 December 2017. New 14 TB LFF HDD and 6-pack bundle. I have an MSA 1000 Shelf with a single controller. I've found documenation and install cpqacuxe, hpacucli and hpsmh (started service hpsmhd and cpqacuxe -R). Slide the back end of the left rack rail into the inside rear of the rack. Most lower end storage products have a 3 year sales run, with another 2-4 years of extended support, but this is really just part swaps not updates to keep relevant with the newer platforms. I am currently running VI3 on an MSA1000 dual Raid controller / disk shelf setup. Those drives are assigned to a MS W3K cluster and its working fine. I´m connecting a MSA1000 with a Dell poweredge 2850. System 2 MSA2000 connected to 2 HP SAN 8/20q switches, there are no ISL links between to two switches. Part number: 257547–003 Third edition: October 2006. · Hi, I have actualy an HP. . Hi, I might have missed it in the release notes, but once the MSA is upgraded to v7 firmware for Active/Active, is there configuration options to have it operate in Active/Passive state? I ask because there was a note regarding the v7 firmware giving the impression this is not the case, something. Z420 could be be from 5 to 7 years old . Electrical interface. The MSA2000sa is also used as an integral part of the Direct Attach Storage for HP BladeSystem, bringing SAS direct attach storage to the HP BladeSystem c-Class. . x). Supposing the above is possible would it be regarded as best pra. . Get the latest Modular Smart Array (MSA) 1040 End of Service Life (EOSL) information from Park Place Technologies, then contact us for a maintenance quote today! Note: This worksheet and the companion worksheets in the HP StorageWorks MSA1000 installation guide are not prerequisites for installing your MSA1000, but some information on the worksheets is required for zoning, multipathing, future configuration changes, and troubleshooting Fabric Support Infrastructure - The MSA1000, HP QLE220 FC HBA (PN AG527A)) and 4/10q FC Switch supports 2 or 4Gb Fibre Channel fabrics. Page 5: Chapter 3: Array Configuration UtilityI'm having performance issues and am trying to determine what the bottleneck could be in my environment. Because this process involves updating your configuration for the MSA1000, HP recommends performing this task during inactive. Six Proliant Windows 2000 servers are connected to the MSA1000 using FC2101 HBA. This process consists of multiple stages described in this notice. Learn more at the Official Hewlett Packard Enterprise Website. This is the first time I have used more than one storage enclosure. Microsoft Windows 2000. QLA2340 FC HBA (pci-x 133) Workstation (current machine using MSA1000)I have a similar problems where I have a MSA1000 connected multipath Act/Pass on a HP DL580 G2 Windows 2000 ADV server. HP Remote Snap functionality is based on existing Snapshot technology offered by HP 2000 SAN Array products. Dell EMC Converged Systems Life Cycle Milestones End of Life End of Primary Support End of Renewal End of Service Life Dell EMC VxBlock and Vblock System Advanced Management Platform AMP Central for Single System Management (Cisco UCS C220 M6) 31-Dec-2023 31-Dec-2026 31-Dec-2027 31-Dec-2028 AMP Central (Standalone and Integrated Get the latest EOSL information directly to your inbox. redundant power supply, redundant I/O interface, RAID configuration) to support continuous operation. Manufacturer. . HP-SIM reports hardware fault conditions (both failure and pre-failure) and collects. Page 1 Interface user guide This guide details the Command Line Interface (CLI), which is used to configure and manage. thanking you . Please help me out with these question as i want to verify the answers: ----- Q1. End of Support (EOS) The product is Supported, but customer should expect to be able to try to replicate any reported issue on the currently Supported version of the software in their production environment. Learn how third party data center. Learn more at the Official Hewlett Packard Enterprise Website. Hi all, i'm in the process of migrating our MSA1000 from active/passive to active/active. Hi all, Pls teach me, - Why HA in MSA1000 use SAN Switch 2/8 has not ISL? - How to HA in MSA1000 operate? Thanks so much! - 3599060Hi, I Have rp5470 server connected directly to MSA1000 SAN switch. Hello, We've got the following MSA1000 setup : - 1 x MSA1000 (single controller) - 2 x MSA30 Attached Enclosures - 1 x HP 2/16-EL Fibre Switch - 8 servers (5 Windows3 VMWare) with 1 HP Branded (Emulex) HBA installed in each In order to provide better performance edundancy, we thought we'd buy t. This is the reason why your servers cannot discover the MSA1000-controller in ACU. HP Master ASE, Storage, Servers, and Clustering MCSE (NT 4. Join HPE President and CEO Antonio Neri and influential industry leaders to discover the power of AI when it’s edge to cloud. I have two 8 port fibre switches with an ISL. # vgcreate vgdata04 /dev/dsk/c4t0d4 Increased the number of. HP 411044-001 MSA 1000 2 Port Ultra3 I/O Module 70-40495-11. Try to disable an controller over the serial cli of one of the controllers. . Please advice whether this ca. . Then again, your environment might not require it. Page 35 Installation Procedures - for all MSA1000 Deployments 3. We see no new errors being reported at this time trhough our web interface to it. The only thing I have found so far is what I think is the power supply's product number 377815-001 but this doesnt provide any real help. I have 3 servers currently on an MSA1000 with a Sanswitch 16V as the fibre channel switch. Secure the MSA1000 to the rack using the provided thumbscrews on the front of the MSA1000 2. Enhancing the MSA family are the HP ProLiant packaged clusters with Modular Smart Array. I appears to come with a single controller and FC-switch. . But when i directly connects MSA 1000 to Server (HP-DL 380) it works to access storage. 11. 24 x 7 Service hours. The problem is this, I have two ser. May 19, 2010 at 16:50. Thanks in advance for any help. Quorum disks on the HP MSA The FlashSystem V9000 cannot use logical units (LUs) that are exported by the HP. Solved. As always, the MSA1000 comes complete with configuration. Removal from price lists. Hi all, We have just had a disk fail in our MSA1000 which has rebuilt on the hot spare of identical size and speed, however whilst rebuilding one of the logical drives is now reporting corruption, this is the second time this has happened on the same logical drive, it has not occurred on any other. • Increases storage density when used with MSA1000 and MSA1500 MSA30 Overview The HP StorageWorks Modular Smart Array 30 Enclosure family is the newest HP Ultra320 SCSI disk drive storage enclosure, delivering industry-leading data performance, availability, storage capacity and upgradeability to meet the demanding and growing storage needs. From there I have Windows 2003 server Enterprise R2 hosts with Qlogic 2214 HBAs dual connected through the switches. And the 3 server is a not a cluster and is runnin. Products. Has anyone got any id. based on the host's OS AND the MSA firmware version. The rest of the contoller configuration was still intact. I'd give a reseat of the MSA1000-switches a shot, maybe that helps. Visit the HP Store. 3. Server 2003. Jeff. Hi - I have an MSA1000 - but it isn't in a cluster - it is just attached to two machines. For the interconnect options, we will purchase 2 x Gbe2c Ethernet Switch & 2 x HP Brocade SAN 4/12 Switch for reducdant propose. The question is, can I connect a SCSI cable to the SCSI B Connector in the rear, and load drives into the empty B Channel. Effective on 30 April 2021, HP will discontinue all services and support for: This discontinuation of service and support includes the stopping of sale and provision of Customer Self-Repair (CSR) parts or spare parts for the HP discontinued products. DESCRIPTION. I am thinking to propose an MSA1000 based s. Elitedesk 800 G1 could have 6/7 years, so it should be not supported (EOS) anymore by Post-Sales support. What is the proper way to initiate a failover to the standby controller? TIA for any help. Get the latest StorageWorks P2000 MSA G3 End of Service Life (EOSL) information from Park Place Technologies, then contact us for a maintenance quote today!Summary of Contents for HP MSA 2040. 2. The MSA 1060 allows users to take advantage of the latest storage technologies. 00. Note: Documentation titled HP StorageWorks Modular SAN Array 1000 or HP StorageWorks Modular Get the latest EOSL information directly to your inbox. However, when we pull the active controller, the other controller does not switch from standby to active! (We checked this via LED 9 and the CLI). HP P2000 G3 FC MSA Dual Controller Virtualization SAN Starter Kit AP848B Re: MSA1000 to MSA1000 replication As far as I know HP does not provide any kind of SAN-based replication on their low end arrays, and the MSA1000 is the lowest point of the low end. MSA 1 and 6 servers are plugged on Ports 1-8 on both switches. I am very nerous about the very large amoubnt of data on the luns across the three cages. Part Number: 866967-001 Published: June 2016. The first. For my other systems I was easily able to locate a part number for my 6402 Smart Array cache batteries, but I cannot find the part number for the MSA1000 Cache Batteries. 06-03-2020 11:45 AM. Now I 've connected the SAN via an other fiber to a second fileserver; On this new fileserver I'm able to see the arrays and logical drives via the ACU webtool, but can't access these drives by the window. Furthermore the CLI command: SET THIS_CONTROLLER ACTIVE d. Save up to 50 percent on costs with Care Packs. We currently have an MSA1000 hooked to a Windows 2000 Server using a KGPSA-xx HBA via a Fabric Switch 6. QuickSpecs HP MSA P2000 G3 Modular Smart Array Systems Models c04168365 — DA – 13551 Worldwide — Version 42 — December 1, 2014 Page 6 (AJ836A ). Description. 3. xx is required for Secure Path 4. I did a search on Google and found good threads in this community but it left me confused. View and Download HP Storageworks msa1000 installation manual online. Cabling HPE Storeeasy 1000 Storage. it finally ran out of space and we're looking to add an expansion. Hi Guys, Can anyone of you help, I have a MSA1000 attach to a rp7400 and a N4000. Installing the HPE Storeeasy 1000 Storage Hardware. Poly will periodically discontinue or transition the sale of certain products and related services. Otherwise you may consider HP EVA with Continous Access feature for storage-based remote replication (or another vandor products from mid to high-end range). The Office 365 SMTP email solution is above domain and not an IP address. I'm getting transfer speeds in the 40-80MB/s. All-flash and Hybrid Storage. Overview. It includes the MSA1000 itself along with the unique MSA SAN Switch 2/8 embedded option, two of the FCA2214 Host Bus Adapters for Windows, NetWare or Linux servers, SFPs and cabling. The HPE MSA 2040 End of Life has passed, and it’s time to start thinking about a continuity plan before the HPE MSA 2040 EOSL hits on April 30th, 2023. Explore our database of over 20,000 parts & never miss a critical date again. Our [partially] retired MSA has one shelf of 14 x 146GB configured as a single 1. Array 1000 (MSA1000), the Modular Smart Array 500 (MSA500), and the Modular Smart Array 30 (MSA30). Could someone possibly point me in the right direction as I am find it very difficult to source this part. Explore our database of over 20,000 parts & never miss a critical date again. Request a quote from our team today. Es posible adquirir por separado un Controlador adicional redundante. I hate to let that MSA1000 just sit there, I would love to use it for some DEV/QA/UAT or DR Testing. HP Master ASE, Storage, Servers, and Clustering MCSE (NT 4. I've a replacement, but how can I savely switch to the non active redundant switch? 2. HP StorageWorks EVA M6625 2. evt log it will show. There are two choices. HP Inc and HPE are separate companies. . Hi , I have installed an MSA1000 and connect it to an rp7XXX HP-UX 11. The server lost access to it's san drives for a whi. . Anyone knows if the MSA1000 with a/p firmware v4. 2. 32 to 4. The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1" universal disk. 1B Due to a rack re-organisation, the MSA had to be powered off (server shutdown followed by controller shelf followed by unplugging of. Chopper3. 3-2 with last version patches installed. 48 (ACTIVE/PASSIVE mode) to the version 7. 11. IT Financing and Investment Services. These are interconnected through HP 2/8-EL switches. Server is running HPUX 11i and has two hba cards that attached and it sees them in ioscan. Get the latest MSA P2000 G3 End of Service Life (EOSL) information from Park Place Technologies, then contact us for a maintenance quote today! Page 1 HP StorageWorks 1000 Modular Smart Array maintenance and service guide This guide provides procedures and diagnostics needed for the maintenance, service, and troubleshooting of the HP StorageWorks 1000 Modular Smart Array (MSA1000 or MSA). hp storageworks msa2 300gb 3g 15k rpm 3. DESCRIPTION. hp StorageWorks Modular Smart Array 1000 (MSA1000) Controller First Edition (September 2003) Part Number: 347281-001 This guide provides the user with information needed to use, replace and maintain the HP StorageWorks Modular Smart Array 1000 Controller. Campus and Branch Networking; Data Center Networking; Small and Midsize Business NetworkingHi there I have a difficult problem to sort out. HP customer has a dual-controller MSA1000 running firmware 5. I have an HP MSA1000 Drive array that is fiber linked to a Windows Cluster running NT4. 4. HPE MSA Storage - CUSTOMER ADVISORY - Certain Midline Hard Drives May Become Unresponsive When Using Earlier Versions of Drive Firmware. MSA1500 firmware, which differs from MSA1000 firmware in that adds support for SATA drives, does support active/active. . Don’t fall under the mistaken belief that a hardware refresh is your sole option when the HPE MSA 1050 SAN Storage End of Service Life matures – other HPE hardware. Interoperability between the new third gen nodes and the previous G2 nodes is provided by running the latest software platform, HP LeftHand OS 10. . All works fine :) But how to manage HP Array on MSA1000? This is an old unsupported product. I have a test server with W2008 installed and I want to set the server up to be the file server. 11. We have an MSA 1000 with 2 controllers. Our [partially] retired MSA has one shelf of 14 x 146GB configured as a single 1. HP MSA1000 Controller with 256MB Cache . . I have a DELL PowerVault 51F Fibre Switch that currently can see HP tape devices and a Windows 2000 Server. The MSA 1000 have two controllers and still i want to know that wht should i use 1. The MSA1000 SAN Starter Kit provides an easy and inexpensive way to build a Storage Area Network. Typically the end of life will become public when it has happened. Call-to-Repair in up to 4 hours. Hello possibly this has been answered in the past, but i cannot find a clear answer anywhere, I am newbie with SAN architecture and trying to learn things. . Effective on 30 April 2021, HP will discontinue all services and support for: This discontinuation of service and support includes the stopping of sale and provision of Customer Self-Repair (CSR) parts or spare parts for the HP discontinued products. As. If your HPE hardware is on this list, contact us today to discuss your options. Operating system on every server is Windows 2003 server. When I look at OS System. Request a quote from our team today. HPE Networking product life cycle milestones: The date after which a product is no longer available for purchase from Hewlett Packard Enterprise Company, its worldwide subsidiaries, affiliates, authorized resellers, or country distributors. Solutions . As always, the MSA1000 comes complete with configuration. . I have added the MSA30 to my Dual Path MSA1000, and powered it up, but only drives 8-14 on bay 3 are identified by the MSA1000 controller, and therefore the ACU. Page 1 HP StorageWorks 1000 Modular Smart Array maintenance and service guide This guide provides procedures and diagnostics needed for the maintenance, service, and troubleshooting of the HP StorageWorks 1000 Modular Smart Array (MSA1000 or MSA). Midrange and Enterprise Storage. The HPE MSA 2052 EOL and EOSL can have an impact on your data center ops, but you have continuity options. Maximum number of drives. I have used IOMeter on a vmware server attached to the MSA in RAID 10 w/ 6x 146GB. 48) 2 x San Switch 2/16-EL (FW:3. I have configure MSA1000 with one logical drive and i configure all servers to have access to logical drive via Array Configuration Utility Selective Storage Presentation (SSP). i recomend you confine your search for EOL to only the models you actually require and then google each model to read the archived articles to determine the release month/year consumer models ar usually 1 year busineness. I have an MSA 1000 with the A Channel filled with 300GB Drives. I would like to extend Logical Drive 2. drives in a single 4U rackmount cabinet. x) RHCE. 48 and Active/Active 7. Couple of questions: 1. Dear all, We have a SAN using a MSA1000 fitted with 5 146g disks, this logical drive is know as drive E: in the Windows 2000 Server and is approx. Does MSA supports is Active/Active, if so how dowe change it from active/passive into active/active? Is it done through some command or through firmware upgrade?There will be a new MSA1000 FW in a few days. This MMIC is designed for use in a push-pull configuration in a 25 Ω system. . Hello, We lost power (I think) to one or both of our controllers in an active/standby setup on an MSA1000. End of Contract Availability. Never miss another End of Service Life announcement Get the latest EOSL information directly to your inbox Upcoming HPE EOSL Dates Model EOSL Date; D2700 Disk Enclosure : 12 / 01 / 2023 : Simplivity 380 Gen 9 Nodes : 12 / 31 / 2023. HPE MSA 1050 SAN Storage Specifications. Use "DELETE CONNECTION name" to get rid of the old one. StoreVirtual 4730. Modular Smart Array 1000 (MSA1000) Command Line Interface First Edition (September 2003) Part Number: 347282-001. 2. Tags: 12-06-2022 10:13 AM. Drive description. Page 1 HPE MSA 1040/2040 Storage Troubleshooting Guide Abstract This document provides information about troubleshooting HPE MSA 1040/2040 Storage. 2 of the servers are in a Windows 2003 cluster. 6TB array. MSA1000 & Windows . answered May 19, 2010 at 16:44. The MSA is new to the windows environment and windows will be the only OS attached to it. both OS and firmware are fully patched. 48 firwmare on HP web. $325. I have installed many of these in environment of upto 4 nodes and can state that performance was acceptable to the end client. HP StorageWorks Modular Smart Array 1500 cs - Installation Procedures. HP Best Practices guide says to use latest firmaware but minimum of 4. HP StorageWorks P2000 Remote Snap Software offers controller‑based, asynchronous replication technology that provides local or remote replication between two HP StorageWorks P2000 G3 FC MSA Arrays. The HPE MSA 2050 end of life and end of service can impact your data center operations, but you have options. Park Place Technologies makes it easy to find the latest End of Life (EOL) and End of Service Life (EOSL) information for your HPE hardware. Think about it: the MSA does not know if this is a replacement or a new adapter in a new server. When this is plugged back in the MSA will compare the two F/W's and prompt to ROM Clone to the older controller.